| Model |
LSU – 13, 152, 23, 252, 33, 53 |
| Rated Load Capacity |
1000, 1500, 2000, 2500, 3000, 5000 kgs |
| Rated Output Sensitivity |
2mV/V ± 0.3% |
| Input Resistance |
350 ± 10 Ohms |
| Output Resistance |
350 ± 5 Ohms |
| Excitation Voltage |
10 to 15 Volts DC/AC (RMS) |
| Non-Linearity |
± 0.025% of Rated Output |
| Hysteresis |
0.025% of Rated Output |
| Creep |
0.01% of Rated Output |
| Non-Repeatability |
± 0.05% of Rated Output |
| Zero Balance |
2% of Rated Output |
| Operatable Temperature Range |
-20°C to 65°C |
| Compensated Temperature Range |
0°C to 55°C |
| Temperature Effect on Zero |
0.005% of Rated Output/°C |
| Temperature Effect on Output |
0.005% of Rated Output/°C |
| Over Load Rating, Safe |
150% of Rated Capacity |
| Power Load Rating (Ultimate) |
200% of Rated Capacity |
| Protection Class |
IP66 |